Substation Scout

North Anna

Named in 10 PJM planning documents for 9 projects, from October 8, 2024 to October 6, 2026.

Existingdescribed as
DOMzone
230 kV, 230kV, 500 kV, 500kVkV as printed
13mentions

Also printed as: North Anna substation

Projects naming this substation

Figures are from the most recent document naming each project, as printed. Each links to its page.

ProjectStatus as printedCost estimateIn-service dateCustomer loadAs of
Dominion Transmission Zone: Baseline New 500kV Line North Anna - Thornburg - Bristers
b4000.344 & b4000.345
Not printed $661.63M 9/16/2030 Not printed 2026-05-08
TEAC
Dominion Transmission Zone: Baseline New 765/500/230kV Yeat Substation
B4000.355 – B4000.359
Not printed $1,109.89M 6/1/2029 Not printed 2026-04-07
TEAC
Regional Solution: 2025-W1-275 Portfolio
b4053.1
Not printed $4832.45 6/1/2032 Not printed 2026-01-06
TEAC
Replace North Anna Substation Breakers and Switches
DOM-2022-0052 · s3058
Not printed $2.36 M 07/27/2023 Not printed 2024-10-08
TEAC
Southall 230kV Delivery - REC
DOM-2023-0017 · s3072
Engineering $55.0 M 05/01/2025 100 MW 2024-10-08
TEAC
Dominion Transmission Zone: Supplemental Operational Flexibility and Efficiency
DOM-2025-0028
Not printed Not printed Not printed Not printed 2025-06-05
TEAC
Do No Harm Analysis
DOM-2025-0071-DNH · s3997.3, s3997.4
Conceptual $12M 12/30/2028 Not printed 2026-10-06
TEAC
Install 230 kV Conductor on North Anna to Bristers Structures
DOM-2026-0022 · s4032
Engineering $33.75 M Q4 2030 Not printed 2026-10-06
TEAC
Dominion Transmission Zone: Baseline Regional Solution: 2025-W1-275 Portfolio
2025-W1-275
Not printed Not printed 6/1/2032 Not printed 2025-12-08
TEAC

Changes between documents

Where two documents print different values for the same project. A large change in a cost estimate can reflect a need being combined with others into one solution, not only a re-estimate; read both pages.

What changedPrinted valuesEarlierLater
Cost estimate
prior value printed on the same page
$704.25 M → $704.33 M 2025-01-07 2025-01-07
Cost estimate
prior value printed on the same page
$571.63M → $661.63M 2026-05-08 2026-05-08
Cost estimate $704.33 M → $661.63M 2025-01-07 2026-05-08
In-service date 6/1/2029 → 9/16/2030 2025-01-07 2026-05-08
Substations named ELMONT; KRAKEN; LADYSMITH; NORTH ANNA; POSSUM POINT; YEAT → AQUIA HARBOR; BRISTERS; KRAKEN; LADYSMITH; NORTH ANNA; STAFFORD; THORNBURG 2025-01-07 2026-05-08
Cost estimate
prior value printed on the same page
$1,055.3 M → $1,109.89M 2025-01-07 2025-01-07
Cost estimate
prior value printed on the same page
$1,109.89M → $978.76 M 2026-08-04 2026-08-04
Cost estimate $1,109.89M → $978.76 M 2026-05-08 2026-08-04
Substations named BRISTERS; ELK RUN; JOSHUA FALLS; MEADOWBROOK; VINT HILL; YEAT → BRISTERS; CULPEPER YEAT; CUNNINGHAM; ELK RUN; ELMONT; JOSHUA FALLS; KRAKEN; MEADOWBROOK; MIDLOTHIAN; MORRISVILLE; MOSBY; NOKESVILLE; NORTH ANNA; POSSUM PT; SPOTSYLVANIA; VINT HILL; VONTAY; WISHING STAR; YEAT 2025-01-07 2026-04-07
Substations named BRISTERS; CULPEPER YEAT; CUNNINGHAM; ELK RUN; ELMONT; JOSHUA FALLS; KRAKEN; MEADOWBROOK; MIDLOTHIAN; MORRISVILLE; MOSBY; NOKESVILLE; NORTH ANNA; POSSUM PT; SPOTSYLVANIA; VINT HILL; VONTAY; WISHING STAR; YEAT → ANDERSON BRANCH; BRISTERS; CULPEPER YEAT; ELK RUN; ELMONT; JOSHUA FALLS; KRAKEN; MEADOWBROOK; MORRISVILLE; MOSBY; NOKESVILLE; POSSUM PT; SPOTSYLVANIA; VINT HILL; VONTAY; WISHING STAR; YEAT 2026-04-07 2026-05-08
Substations named ANDERSON BRANCH; BRISTERS; CULPEPER YEAT; ELK RUN; ELMONT; JOSHUA FALLS; KRAKEN; MEADOWBROOK; MORRISVILLE; MOSBY; NOKESVILLE; POSSUM PT; SPOTSYLVANIA; VINT HILL; VONTAY; WISHING STAR; YEAT → BRISTERS; CLOVERDALE; ELK RUN; JOSHUA FALLS; MEADOWBROOK; VINT HILL; YEAT 2026-05-08 2026-08-04
Substations named FOXBROOK LANE; FRANCES; GORDONSVILLE; N ANNA; NORTH ANNA; SOUTHALL → FRANCES; NORTH ANNA; SOUTHALL 2026-01-06 2026-10-06
Substations named BRISTERS; ELMONT; FREDERICKSBURG; NORTH ANNA; THORNBURG → BRISTERS; NORTH ANNA; THORNBURG 2026-06-02 2026-10-06

Every mention

DateDocumentProjectWhat the document says about it
2026-10-06 TEAC
Informational Only - Dominion Local Plan Submission of the Supplemental Projects 2026 p. 64
Do No Harm Analysis “Expand North Anna substation to terminate the new 230 kV line”
230 kV
2026-10-06 TEAC
Informational Only - Dominion Local Plan Submission of the Supplemental Projects 2026 p. 81
Install 230 kV Conductor on North Anna to Bristers Structures No role wording
2026-09-08* SRRTEP Southern
Dominion p. 130
Southall 230kV Delivery - REC “Line #255 (North Anna - Desper)”
2026-09-08* SRRTEP Southern
Dominion p. 92
Replace North Anna Substation Breakers and Switches “Replace the following 230kV equipment at North Anna Substation”
230kV
2026-06-02 TEAC
Item 11 - DOM Supplemental Projects p. 7
Install 230 kV Conductor on North Anna to Bristers Structures No role wording
2026-05-08 TEAC
Item 10 - Reliability Analysis Update p. 14
Dominion Transmission Zone: Baseline New 500kV Line North Anna - Thornburg - Bristers “Build a 500kV line from North Anna substation”
500kV
2026-04-07 TEAC
Item 11 - Reliability Analysis Update p. 16
Dominion Transmission Zone: Baseline New 765/500/230kV Yeat Substation No role wording
500 kV
2026-01-06 TEAC
Item 07 - DOM Supplemental Projects p. 19
Do No Harm Analysis “Expand North Anna substation”
230 kV
2026-01-06 TEAC
Item 09 - Reliability Analysis Update p. 37
Regional Solution: 2025-W1-275 Portfolio “Rebuild 500 kV line 576 from North Anna Substation to Vontay Substation.”
500 kV
2025-12-08 TEAC
Item 11 - Reliability Analysis Update p. 83
Dominion Transmission Zone: Baseline Regional Solution: 2025-W1-275 Portfolio “Rebuild 500 kV line 576 from North Anna Substation”
500 kV
2025-06-05 TEAC
Item 08 - DOM Supplemental Projects p. 3
Dominion Transmission Zone: Supplemental Operational Flexibility and Efficiency No role wording
2024-10-08 TEAC
Informational Only - DOM Local Plan submission of supplemental projects 2024 p. 130
Southall 230kV Delivery - REC No role wording
2024-10-08 TEAC
Informational Only - DOM Local Plan submission of supplemental projects 2024 p. 91
Replace North Anna Substation Breakers and Switches “Replace the following 230kV equipment at North Anna Substation”
230kV

* A local-plan posting carries no meeting date; the date shown is when pjm.com last modified the file.

Before relying on any of this