Substation Scout

Clifton

Named in 5 PJM planning documents for 4 projects, from May 6, 2025 to September 8, 2026.

Existingdescribed as
DOMzone
230 kV, 230kVkV as printed
5mentions

Projects naming this substation

Figures are from the most recent document naming each project, as printed. Each links to its page.

ProjectStatus as printedCost estimateIn-service dateCustomer loadAs of
Regional Solution: 2025-W1-275 Portfolio
b4053.1
Not printed $4832.45 6/1/2032 Not printed 2026-01-06
TEAC
Do No Harm (DNH) Analysis
DOM-2022-0045-DNH · s3035.2
Conceptual $139.0M (Total) 12/31/2027 Not printed 2026-09-08*
SRRTEP Southern
Dominion Transmission Zone: Supplemental Do No Harm Analysis
DOM-2024-0063-DNH
Conceptual $24.0M 06/01/2029 Not printed 2025-05-06
TEAC
Dominion Transmission Zone: Supplemental Equipment Material Condition, Performance Risk
DOM-2026-0016
Conceptual Not printed Not printed Not printed 2026-09-08
TEAC

Changes between documents

Where two documents print different values for the same project. A large change in a cost estimate can reflect a need being combined with others into one solution, not only a re-estimate; read both pages.

What changedPrinted valuesEarlierLater
Substations named BRISTERS; HORNBAKER; NOKESVILLE; VINT HILL → BRICKYARD; BRISTERS; CLIFTON; DAWKINS BRANCH; GAINESVILLE; HORNBAKER; NOKESVILLE; RAILROAD; VINT HILL 2024-10-08 Not reported
Substations named BRICKYARD; CLIFTON; DEVLIN; GAINESVILLE; NOKESVILLE; RAILROAD; ROLLINS FORD; VINT HILL; WHEELER → DEVLIN; GAINESVILLE; VINT HILL; WHEELER 2025-05-06 2025-10-08

Every mention

DateDocumentProjectWhat the document says about it
2026-09-08 TEAC
Item 10 - DOM Supplemental Projects p. 6
Dominion Transmission Zone: Supplemental Equipment Material Condition, Performance Risk “Replace the 230 kV cap banks at Liberty, Clifton, Greenwich, Lanexa, Pleasant View, Jefferson Street, Valley and Newport News”
230 kV
2026-09-08* SRRTEP Southern
Dominion p. 60
Do No Harm (DNH) Analysis No role wording
2026-04-07 TEAC
Item 09 - DOM Supplemental Projects p. 5
Dominion Transmission Zone: Supplemental Equipment Material Condition, Performance Risk “cap banks needing replacement between 2027 and 2028 are located at Pleasant View, Greenwich, Liberty, Clifton”
230 kV
2026-01-06 TEAC
Item 09 - Reliability Analysis Update p. 41
Regional Solution: 2025-W1-275 Portfolio “Clifton Sub 230kV: Replace 63kA breakers 205182, 2051T2063, 221282 with 80kA.”
230kV
2025-05-06 TEAC
Item 09 - DOM Supplemental Projects p. 13
Dominion Transmission Zone: Supplemental Do No Harm Analysis No role wording

* A local-plan posting carries no meeting date; the date shown is when pjm.com last modified the file.

Before relying on any of this