Substation Scout

Wylie Ridge Substation

Named in 13 PJM planning documents for 9 projects, from October 8, 2024 to October 6, 2026.

Existingdescribed as
APSzone
138 kV, 345/138 kV, 500 kV, 500/345 kVkV as printed
23mentions

Also printed as: Wylie Ridge

Projects naming this substation

Figures are from the most recent document naming each project, as printed. Each links to its page.

ProjectStatus as printedCost estimateIn-service dateCustomer loadAs of
Misoperation Relay Projects
APS-2023-064 · s3158.1
Not printed Not printed Not printed Not printed 2024-10-08
TEAC
Misoperation Relay Projects
APS-2023-064 to APS-2023-066, APS-2023-069
Not printed $1.7 06/01/2024 Not printed 2026-09-08*
SRRTEP Western
Misoperation Relay Projects
APS-2024-005, APS-2024-006 · s3464.1, s3465.1
Not printed Not printed Not printed Not printed 2024-10-08
TEAC
Weirton - Wylie Ridge 138 kV Misoperation Relays
APS-2024-025 · s3771.1
Not printed $4.50M 07/20/2029 Not printed 2026-10-06
TEAC
Wylie Ridge No. 3 345/138 kV Transformer
APS-2024-079 · s3870.1
Not printed $13.45M 12/13/2030 Not printed 2026-10-06
TEAC
Wylie Ridge No. 7 500/345 kV Transformer
APS-2024-080 · S3654.1
Not printed $ 20 M 12/13/2030 Not printed 2025-10-08
TEAC
Misoperation Relay Projects
APS-2024-098 to 105, APS-2024-111 to 114, APS-2024-116, APS-2024-118
Not printed Not printed Not printed Not printed 2024-12-13
SRRTEP Western
Misoperation Relay Projects
APS-2024-116 · s3643.1, s3643.2
Not printed $7.04 M 04/27/2029 Not printed 2025-10-08
TEAC
Arroyo - East Liverpool – Wylie Ridge 138 kV Switch
APS-2024-119 · s3647.1
Not printed $1.1 M 05/09/2025 Not printed 2025-10-08
TEAC

Changes between documents

Where two documents print different values for the same project. A large change in a cost estimate can reflect a need being combined with others into one solution, not only a re-estimate; read both pages.

What changedPrinted valuesEarlierLater
Substations named HARRISON; MT STORM DOM; PRUNTYTOWN; WYLIE RIDGE → HARRISON; PRUNTYTOWN; WYLIE RIDGE 2024-10-08 Not reported
Substations named ARROYO; ARROYO JUNCTION; EAST LIVERPOOL; SOUTH CHESTER TAP; WYLIE RIDGE → ARROYO; EAST LIVERPOOL; WYLIE RIDGE 2024-12-13 2025-03-14
Substations named ARROYO; EAST LIVERPOOL; WYLIE RIDGE → ARROYO JUNCTION; EAST LIVERPOOL; SOUTH CHESTER TAP; WYLIE RIDGE 2025-03-14 2025-10-08

Every mention

DateDocumentProjectWhat the document says about it
2026-10-06 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2026 p. 11
Weirton - Wylie Ridge 138 kV Misoperation Relays “Replace 138 kV circuit breakers, disconnect switches, line trap, substation conductor, CCVT, and relaying at Wylie Ridge Substation”
138 kV
2026-10-06 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2026 p. 39
Wylie Ridge No. 3 345/138 kV Transformer “At Wylie Ridge Substation: Replace the No. 3 345/138 kV Transformer”
345/138 kV
2026-09-28* SRRTEP Western
APS local plan submission of the supplemental projects for 2026 RTEP p. 11
Weirton - Wylie Ridge 138 kV Misoperation Relays “relaying at Wylie Ridge Substation”
2026-09-28* SRRTEP Western
APS local plan submission of the supplemental projects for 2026 RTEP p. 39
Wylie Ridge No. 3 345/138 kV Transformer “At Wylie Ridge Substation: Replace the No. 3 345/138 kV Transformer”
345/138 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2024 RTEP p. 114
Misoperation Relay Projects “At Wylie Ridge, replace line trap and relaying”
500 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2024 RTEP p. 61
Misoperation Relay Projects “At Wylie Ridge Substation, replace circuit breaker, disconnect switches, line trap and relaying”
138 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2025 RTEP p. 28
Misoperation Relay Projects “Wylie Ridge Substation: At Wylie Ridge, replace circuit breaker”
138 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2025 RTEP p. 36
Arroyo - East Liverpool – Wylie Ridge 138 kV Switch No role wording
138 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2025 RTEP p. 43
Wylie Ridge No. 7 500/345 kV Transformer “Replace No. 7 500/345 kV Transformer at Wylie Ridge Substation”
500/345 kV
2025-11-04 TEAC
Item 04 - APS Supplemental Projects - Version 7 p. 8
Wylie Ridge No. 3 345/138 kV Transformer “At Wylie Ridge Substation: Replace the No. 3 345/138 kV Transformer”
345/138 kV
2025-10-08 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2025 p. 28
Misoperation Relay Projects “At Wylie Ridge, replace circuit breaker, disconnect switches”
138 kV
2025-10-08 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2025 p. 36
Arroyo - East Liverpool – Wylie Ridge 138 kV Switch No role wording
138 kV
2025-10-08 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2025 p. 43
Wylie Ridge No. 7 500/345 kV Transformer “Replace No. 7 500/345 kV Transformer at Wylie Ridge Substation”
500/345 kV
2025-08-15 SRRTEP Western
Item 04 - APS Supplemental Projects p. 8
Weirton - Wylie Ridge 138 kV Misoperation Relays “Replace 138 kV circuit breakers, disconnect switches, line trap, substation conductor, CCVT, and relaying at Wylie Ridge Substation”
138 kV
2025-04-01 TEAC
Item 04 - APS Supplemental Projects p. 10
Wylie Ridge No. 7 500/345 kV Transformer “Replace No. 7 500/345 kV Transformer at Wylie Ridge Substation”
500/345 kV
2025-03-14 SRRTEP Western
Item 07 - APS Supplemental Project p. 13
Arroyo - East Liverpool – Wylie Ridge 138 kV Switch No role wording
138 kV
2025-02-14 SRRTEP Western
Item 04 - APS Supplemental Projects p. 8
Misoperation Relay Projects “At Wylie Ridge, replace circuit breaker, disconnect switches, wave trap, substation conductor, line turner and coax, and relaying.”
138 kV
2024-12-13 SRRTEP Western
Item 15 - APS Supplemental Project p. 6
Misoperation Relay Projects No role wording
138 kV
2024-12-13 SRRTEP Western
Item 15 - APS Supplemental Project p. 7
Arroyo - East Liverpool – Wylie Ridge 138 kV Switch No role wording
138 kV
2024-11-06 TEAC
Item 04 - APS Supplemental Projects p. 3
Wylie Ridge No. 3 345/138 kV Transformer No role wording
345/138 kV
2024-11-06 TEAC
Item 04 - APS Supplemental Projects p. 4
Wylie Ridge No. 7 500/345 kV Transformer No role wording
500/345 kV
2024-10-08 TEAC
Informational Only - APS Local Plan submission of supplemental project 2024 p. 114
Misoperation Relay Projects “At Wylie Ridge, replace line trap and relaying”
500 kV
2024-10-08 TEAC
Informational Only - APS Local Plan submission of supplemental project 2024 p. 61
Misoperation Relay Projects “At Wylie Ridge Substation, replace circuit breaker, disconnect switches, line trap and relaying”
138 kV

* A local-plan posting carries no meeting date; the date shown is when pjm.com last modified the file.