Houseville Substation

Named in 6 PJM planning documents for 5 projects, from October 8, 2024 to October 8, 2025.

Existingdescribed as
APSzone
138 kVkV as printed
6mentions

Also printed as: Houseville

Projects naming this substation

Figures are from the most recent document naming each project, as printed. Each links to its page.

ProjectStatus as printedCost estimateIn-service dateCustomer loadAs of
Misoperation Relay Projects
APS-2023-036, APS-2023-041 to APS-2023-043, APS-2023-045 to APS-2023-049
Not printed $2.2 M 11/29/2024 Not printed 2026-09-08*
SRRTEP Western
Misoperation Relay Projects
APS-2023-048 · s3114.1
Not printed Not printed Not printed Not printed 2024-10-08
TEAC
Misoperation Relay Projects
APS-2024-098 to 105, APS-2024-111 to 114, APS-2024-116, APS-2024-118
Not printed Not printed Not printed Not printed 2024-12-13
SRRTEP Western
Misoperation Relay Projects
APS-2024-098 to APS-2024-100, APS-2025-015
Conceptual Not printed Not printed Not printed 2025-06-13
SRRTEP Western
Misoperation Relay Projects
APS-2024-100 · s3709.1
Not printed $3.4 12/31/2027 Not printed 2025-10-08
TEAC

Changes between documents

Where two documents print different values for the same project. A large change in a cost estimate can reflect a need being combined with others into one solution, not only a re-estimate; read both pages.

What changedPrinted valuesEarlierLater
Substations named FRANKLIN; PURSELY → ARMSTRONG; CABOT; EDGELAWN; FAIRVIEW; FRANKLIN; GILBOA; GRASSY FALLS; HOUSEVILLE; MCCALMONT; PRICE HILL; PRUNTYTOWN; PURSELY; SUTTON; TRISSLER 2024-10-08 Not reported

Every mention

DateDocumentProjectWhat the document says about it
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2024 RTEP p. 51
Misoperation Relay Projects “At Houseville Substation, replace circuit breaker, disconnect switches, substation conductor and relaying”
138 kV
2026-09-08* SRRTEP Western
APS local plan submission of the supplemental projects for 2025 RTEP p. 54
Misoperation Relay Projects “At Houseville Substation, replace disconnect switches”
138 kV
2025-10-08 TEAC
Informational Only - APS Local Plan Submission of the Supplemental Projects for 2025 p. 54
Misoperation Relay Projects “At Houseville Substation, replace disconnect switches, line trap”
138 kV
2025-06-13 SRRTEP Western
Item 06 - APS Supplemental Projects p. 6
Misoperation Relay Projects “At Houseville Substation, replace disconnect switches”
138 kV
2024-12-13 SRRTEP Western
Item 15 - APS Supplemental Project p. 5
Misoperation Relay Projects No role wording
138 kV
2024-10-08 TEAC
Informational Only - APS Local Plan submission of supplemental project 2024 p. 51
Misoperation Relay Projects “At Houseville Substation, replace circuit breaker, disconnect switches, substation conductor and relaying”
138 kV

* A local-plan posting carries no meeting date; the date shown is when pjm.com last modified the file.