Windsor
Named in 2 PJM planning documents for 2 projects, from February 4, 2025 to May 8, 2026.
Existingdescribed as
PSEGzone
230 kVkV as printed
2mentions
Also printed as: Windsor Substation
Projects naming this substation
Figures are from the most recent document naming each project, as printed. Each links to its page.
| Project | Status as printed | Cost estimate | In-service date | Customer load | As of |
|---|---|---|---|---|---|
| PSEG Transmission Zone: NJ SAA Baseline Project Cancelations b3737.40 |
Not printed | Not printed | 6/1/2029 | Not printed | 2026-05-08 TEAC |
| b3737.41 Cancellation: Windsor – Clarksville 230kV b3737.41 |
Cancelled | $1.49M | Not printed | Not printed | 2025-02-04 TEAC |
Every mention
| Date | Document | Project | What the document says about it |
|---|---|---|---|
| 2026-05-08 | TEAC Item 10 - Reliability Analysis Update p. 31 |
PSEG Transmission Zone: NJ SAA Baseline Project Cancelations | “Windsor Substation with double bundled 1590 ACSR conductor” |
| 2025-02-04 | TEAC Item 12 - Reliability Analysis Update p. 10 |
b3737.41 Cancellation: Windsor – Clarksville 230kV | “upgrading all terminal equipment at Windsor 230 kV” 230 kV |
* A local-plan posting carries no meeting date; the date shown is when pjm.com last modified the file.
Before relying on any of this
- Names are machine-extracted from PDFs by a language model. Every exported name was checked to be printed in the PDF text; names read only from maps or diagrams are excluded.
- An entry is a name within a transmission zone, not a verified physical facility. The same name in two zones is two entries; spelling variants are merged only when they differ by punctuation, case or a generic suffix such as "Substation".
- role is "new" only where a cited document phrase describes the substation as new or describes constructing it, "existing" where a phrase describes work at it, otherwise "unknown".
- Costs, dates, statuses and loads are the documents' own printed values for the most recent document that names the substation. Each one shipped here is printed on its cited page ("verification": "exact" or "on-page"); values that failed that check are withheld and counted in figures_withheld_unverified. None has been reviewed by a person.
- Zone is the transmission owner whose deck presented the project. PJM-SYSTEM marks names from PJM's own reliability decks, which span zones.
- A printed customer load is the amount a document states for a request. It says nothing about the substation's capability.