Ballinger
Named in 5 listed projects in ERCOT’s transmission project tracking workbook, in Runnels County. First named in the release with data as of June 1, 2017.
Runnelscounty as printed
69, 138kV
AEP TNCutility
5projects listed
No HIFLD substation record has this name in this county.
Generation interconnection requests filed in Runnels, TX: ERCOT queue, 8 active of 8. Same county, not the same substation.
Projects naming this substation
As the utility reported them in the current release. The tab is ERCOT’s; the status is the utility’s.
| Project | Utility | Status as reported | kV | Projected in service | Terminals | Substations named |
|---|---|---|---|---|---|---|
| Ballinger: Rebuild 138 kV Station Rehab the 138/69 kV autotransformer at Ballinger ERCOT project 48818 · utility no. 2777 |
AEP TNC Tier 4 |
Planned Future tab |
138 | Jun 2027 | Ballinger Runnels County |
Ballinger |
| Ballinger to Concho: Rebuild 69 kV line Rebuild Ballinger to Concho 69 kV line, install POP switch for Rowena, install CB at Miles, install POP switch for Harriett REA ERCOT project 55421 · utility no. 1861 · RPG 20RPG004 |
AEP TNC Tier 3 |
Under Construction Future tab |
69 | Oct 2027 | Ballinger to San Angelo Concho Runnels / Tom Green County |
Ballinger, San Angelo Concho |
| Ballinger to Eden 69 kV line: Rebuild taps Rebuild Taps on the Ballinger to Eden 69 kV line ERCOT project 6572 · utility no. 2814 |
AEP TNC Tier 4 |
Planned Future tab |
69 | Jun 2027 | Ballinger to Eden Runnels / Concho County |
Ballinger, Eden |
| Ballinger to Santa Anna: Rebuild 69 kV line Rebuild 69 kV line and rebuild taps on the Ballinger to Santa Anna 69 kV line. ERCOT project 70630 · utility no. TA2021193 · RPG 22RPG028 |
AEP TNC Tier 3 |
Planned Future tab |
69 | Mar 2029 | Ballinger to Santa Anna Runnels / Coleman County |
Ballinger, Santa Anna |
| Ballinger to Oak Creek: Reterminate 138 kV Line Into Nicole Reterminate the Ballinger to Oak Creek 138 kV line from Oak Creek into the existing Nicole 138 kV station ERCOT project 98628 · RPG H.B. 5066 |
AEP TNC Tier 1 |
Planned Future tab |
138 | Nov 2029 | Ballinger to Nicole Runnels / Coke County |
Ballinger, Nicole |
Changes between releases
Where two consecutive releases print different values for these projects (last ten releases).
| Release (data as of) | Project | What changed | Printed values |
|---|---|---|---|
| October 1, 2026 | 48818 | Projected in-service date | Jul 2027 → Jun 2027 |
| October 1, 2026 | 55421 | Status as reported | Planned → Under Construction |
| October 1, 2026 | 6572 | Projected in-service date | Jul 2027 → Jun 2027 |
| October 1, 2026 | 70630 | Projected in-service date | Feb 2030 → Mar 2029 |
| June 1, 2026 | 55421 | Projected in-service date | May 2027 → Oct 2027 |
| June 1, 2026 | 70630 | Projected in-service date | Sep 2028 → Feb 2030 |
| February 1, 2026 | 48818 | Projected in-service date | Apr 2026 → Jul 2027 |
| February 1, 2026 | 6572 | Projected in-service date | Mar 2027 → Jul 2027 |
| February 1, 2026 | 98628 | Projected in-service date | Dec 2030 → Nov 2029 |
| October 1, 2025 | 6572 | Projected in-service date | Apr 2026 → Mar 2027 |
| October 1, 2025 | 70630 | Projected in-service date | Nov 2026 → Sep 2028 |
| October 1, 2025 | 98628 | First listed | on the Future tab |
| February 1, 2025 | 48818 | Projected in-service date | Jan 2026 → Apr 2026 |
| February 1, 2025 | 55421 | Projected in-service date | Dec 2026 → May 2027 |
| February 1, 2025 | 6572 | Projected in-service date | Jan 2026 → Apr 2026 |
| October 1, 2024 | 48818 | Projected in-service date | Nov 2025 → Jan 2026 |
| October 1, 2024 | 6572 | Projected in-service date | Nov 2025 → Jan 2026 |
| October 1, 2024 | 70630 | Projected in-service date | Aug 2028 → Nov 2026 |
| June 1, 2024 | 55421 | Projected in-service date | May 2025 → Dec 2026 |
| June 1, 2024 | 70630 | Projected in-service date | Nov 2026 → Aug 2028 |
Source: ERCOT TPIT workbook, data as of October 1, 2026, retrieved 2026-10-26; posting page last checked 2026-11-23. Each row is cited by sheet and row number in the workbook.
Before relying on any of this
- TPIT lists substation work only where it changes a transmission line or autotransformer rating. A new load-serving substation that changes no rating may never appear in it.
- Every value is the Transmission Service Provider's own statement, compiled by ERCOT. Status and in-service dates are not ERCOT determinations.
- The workbook tab (Future, Current-year planned, Completed, Cancelled) is assigned by ERCOT from dates; the status column is the TSP's word. The two can disagree, and both are shown.
- In ERCOT's competitive areas the company named is the transmission and distribution wires company, not a retail electricity provider or a generator.
- ERCOT publishes the workbook about three times a year, plus occasional updates. A substation that is not listed may simply not be reported yet.
- Substation names are read from the workbook's "from" and "to" terminal columns; for rows with neither, from fixed patterns in the title and description. No language model reads this workbook.
- An entry is a name within a county, not a verified physical facility. A link to a HIFLD record means the names and counties agree exactly, not that the two are confirmed to be one facility.
Site Scanner