Ranger Camp
Named in 3 listed projects in ERCOT’s transmission project tracking workbook, in Mitchell County. First named in the release with data as of June 1, 2024.
Mitchellcounty as printed
138, 345kV
ONCORutility
3projects listed
No HIFLD substation record has this name in this county.
Generation interconnection requests filed in Mitchell, TX: ERCOT queue, 17 active of 19. Same county, not the same substation.
Projects naming this substation
As the utility reported them in the current release. The tab is ERCOT’s; the status is the utility’s.
| Project | Utility | Status as reported | kV | Projected in service | Terminals | Substations named |
|---|---|---|---|---|---|---|
| Ranger Camp – Cattleman 345 kV Double-Circuit Line Construct a new 345 kV double-circuit line from Ranger Camp to Cattleman ERCOT project 81274 · utility no. R8648 · RPG 23RPG029 |
ONCOR Tier 1 |
In-Service Completed tab |
345 | Mar 2026 actual 2026-06 |
Ranger Camp to Cattleman Mitchell County |
Ranger Camp, Cattleman |
| Ranger Camp – Prong Moss 345 kV Line Rebuild Rebuild the existing 345 kV line and add a second circuit to the new line ERCOT project 81299 · utility no. R3025 · RPG 23RPG029 |
ONCOR Tier 1 |
Planned Future tab |
345 | Jun 2027 | Ranger Camp to Prong Moss Mitchell / Howard County |
Ranger Camp, Prong Moss |
| Ranger Camp Switch - Barber Lake Switch 138 kV Line (East Circuit, 2nd Circuit) Add Permian Basin Reliability Plan Upgrade ID L22A. Install a new 3.68-mile, 138 kV second conductor on existing double-circuit structures from Ranger Camp to Barber Lake (via Frontier) ERCOT project 99284 · utility no. PB_L22_A |
ONCOR Tier 3 |
Planned Future tab |
138 | Dec 2027 | Ranger Camp to Barber Lake Mitchell County |
Ranger Camp, Barber Lake |
Changes between releases
Where two consecutive releases print different values for these projects (last ten releases).
| Release (data as of) | Project | What changed | Printed values |
|---|---|---|---|
| October 1, 2026 | 81274 | Moved between tabs | Current-year planned → Completed |
| October 1, 2026 | 81274 | Status as reported | Planned → In-Service |
| June 1, 2026 | 81274 | Projected in-service date | Jan 2026 → Mar 2026 |
| February 1, 2026 | 81274 | Projected in-service date | Dec 2025 → Jan 2026 |
| February 1, 2026 | 81299 | Projected in-service date | May 2027 → Jun 2027 |
| October 1, 2025 | 99284 | First listed | on the Future tab |
| June 1, 2025 | 81274 | Moved between tabs | Future → Current-year planned |
| February 1, 2025 | 81299 | Projected in-service date | Dec 2026 → May 2027 |
| June 1, 2024 | 81274 | First listed | on the Future tab |
| June 1, 2024 | 81299 | First listed | on the Future tab |
Source: ERCOT TPIT workbook, data as of October 1, 2026, retrieved 2026-10-26; posting page last checked 2026-11-23. Each row is cited by sheet and row number in the workbook.
Before relying on any of this
- TPIT lists substation work only where it changes a transmission line or autotransformer rating. A new load-serving substation that changes no rating may never appear in it.
- Every value is the Transmission Service Provider's own statement, compiled by ERCOT. Status and in-service dates are not ERCOT determinations.
- The workbook tab (Future, Current-year planned, Completed, Cancelled) is assigned by ERCOT from dates; the status column is the TSP's word. The two can disagree, and both are shown.
- In ERCOT's competitive areas the company named is the transmission and distribution wires company, not a retail electricity provider or a generator.
- ERCOT publishes the workbook about three times a year, plus occasional updates. A substation that is not listed may simply not be reported yet.
- Substation names are read from the workbook's "from" and "to" terminal columns; for rows with neither, from fixed patterns in the title and description. No language model reads this workbook.
- An entry is a name within a county, not a verified physical facility. A link to a HIFLD record means the names and counties agree exactly, not that the two are confirmed to be one facility.