RD Wells
Named in 2 listed projects in ERCOT’s transmission project tracking workbook, in Denton County. First named in the release with data as of June 1, 2016.
Dentoncounty as printed
138kV
DMEutility
2projects listed
No HIFLD substation record has this name in this county.
Generation interconnection requests filed in Denton, TX: ERCOT queue, 1 active of 1. Same county, not the same substation.
Projects naming this substation
As the utility reported them in the current release. The tab is ERCOT’s; the status is the utility’s.
| Project | Utility | Status as reported | kV | Projected in service | Terminals | Substations named |
|---|---|---|---|---|---|---|
| Conversion to 138kV Reconnect the 69kV Hickory - RD Wells to the 138kV Hickory and RD Wells substations. Line is already insulated for 138kV. ERCOT project 5430O · RTP N/A |
DME Tier 4 |
Planned Completed tab |
138 | Jul 2025 actual 2025-07 |
Hickory to RD Wells Denton County |
Hickory, RD Wells |
| Upgrade 138kV DentonWest-RDWells line to 700MVA (SUM2024) ERCOT project 64776 · RPG N/A · RTP N/A |
DME Tier 4 |
Planned Completed tab |
138 | Jul 2025 actual 2025-07 |
RD Wells to Denton West Denton County |
RD Wells, Denton West |
Changes between releases
Where two consecutive releases print different values for these projects (last ten releases).
| Release (data as of) | Project | What changed | Printed values |
|---|---|---|---|
| October 1, 2025 | 5430O | Moved between tabs | Current-year planned → Completed |
| October 1, 2025 | 64776 | Moved between tabs | Current-year planned → Completed |
| June 1, 2025 | 5430O | Moved between tabs | Future → Current-year planned |
| June 1, 2025 | 64776 | Moved between tabs | Future → Current-year planned |
| June 1, 2024 | 64776 | Projected in-service date | Jul 2024 → Jul 2025 |
Source: ERCOT TPIT workbook, data as of October 1, 2026, retrieved 2026-10-26; posting page last checked 2026-11-23. Each row is cited by sheet and row number in the workbook.
Before relying on any of this
- TPIT lists substation work only where it changes a transmission line or autotransformer rating. A new load-serving substation that changes no rating may never appear in it.
- Every value is the Transmission Service Provider's own statement, compiled by ERCOT. Status and in-service dates are not ERCOT determinations.
- The workbook tab (Future, Current-year planned, Completed, Cancelled) is assigned by ERCOT from dates; the status column is the TSP's word. The two can disagree, and both are shown.
- In ERCOT's competitive areas the company named is the transmission and distribution wires company, not a retail electricity provider or a generator.
- ERCOT publishes the workbook about three times a year, plus occasional updates. A substation that is not listed may simply not be reported yet.
- Substation names are read from the workbook's "from" and "to" terminal columns; for rows with neither, from fixed patterns in the title and description. No language model reads this workbook.
- An entry is a name within a county, not a verified physical facility. A link to a HIFLD record means the names and counties agree exactly, not that the two are confirmed to be one facility.
Site Scanner